Cooling Towers
-
S3000 Series (Crossflow)
-
S3000 Series 'Crossflow' Cooling Tower
Capacity Range
Single Cell Capacity from 40 l/s to 260 l/sFan System
Axial Fan, Induced DraftMaximum Entering Fluid Temperature
50°C standard wet deck, 55°C alternative wet deck materialTypical Applications
Medium to large HVAC and industrial applications. Replacement of timber field erected towers.
-
-
PCT Series (Counterflow)
-
PCT Series 'Counterflow' Cooling Tower
Capacity Range
Single Cell Capacity from 40 l/s to 145 l/sFan System
Axial Fan, Induced DraftMaximum Entering Fluid Temperature
55°C standard wet deck, 65°C alternative wet deck materialTypical Applications
Small to medium industrial applications. Dirty Water applications.
-
-
VXT Series (Counterflow)
-
VXT Series 'Counterflow' Cooling Tower
Capacity Range
Single Cell Capacity from 1,6 l/s to 1230 l/sFan System
Centrifugal Fan, Forced DraftMaximum Entering Fluid Temperature
55°C standard wet deck, 65°C alternative wet deck materialTypical Applications
Small to medium HVAC and industrial applications. Indoor installations. High temperature industrial applications. Tight enclosures and installations requiring a single or bottom air inlet.
-
-
VTL Series (Counterflow)
-
VTL Series 'Low Profile Counterflow' Cooling Tower
Capacity Range
Single Cell Capacity from 4 l/s to 90 l/sFan System
Centrifugal Fan, Forced DraftMaximum Entering Fluid Temperature
55°C standard wet deck, 65°C alternative wet deck materialTypical Applications
Small to medium HVAC & Industrial applications. Extremely low height, tight enclosure, indoor or high temperature applications. Installations requiring a single air inlet.
-
-
S3000 Series (Crossflow)
-
Closed Circuit Coolers
-
RCF Series (Counterflow)
-
RCF Series 'Counterflow' Closed Circuit Cooler
Capacity Range
Single Cell Capacity from 1 to 100 l/sFan System
Axial Fan, Induced DraftTypical Applications
Small to medium Industrial applications.
-
-
VXI Series (Counterflow)
-
VXI Series 'Counterflow' Closed Circuit Cooler
Capacity Range
Single Cell Capacity from 1 l/s to 200 l/sFan System
Centrifugal Fan, Forced DraftMaximum Entering Fluid Temperature
82°CTypical Applications
Small to medium HVAC & industrial applications such as water source heat pump loops and air compressor cooling. Indoor installations. High temperature applications. Tight enclosures & installations requiring a single air inlet. Extremely sound sensitive.
-
-
FXV Series (Combinedflow)
-
FXV Series 'Combinedflow' Closed Circuit Cooler
Capacity Range
Single Cell Capacity from 3 l/s to 149 l/sFan System
Axial Fan, Induced DraftMaximum Entering Fluid Temperature
82°CTypical Applications
Small to medium HVAC & industrial applications such as water source heat pump loops and air compressor cooling. Tight enclosures & installations requiring a single air inlet. Unit replacements.
-
-
VFL Series (Counterflow)
-
VFL Series 'Counterflow' Closed Circuit Cooler
Capacity Range
Single Cell Capacity up to 65 l/sFan System
Centrifugal Fan, Forced DraftMaximum Entering Fluid Temperature
82°CTypical Applications
Small to medium HVAC and industrial applications. Tight enclosures and installations requiring a single air inlet. Low high and indoor installations. High temperature industrial applications. Dry operation in winter time. Sound critical installations.
-
-
RCF Series (Counterflow)
-
Evaporative Condensers
-
RCC Series (Counterflow)
-
RCC Series 'Counterflow' Evaporative Condenser
Capacity Range
Single Cell Capacity up to 2700kWFan System
Axial Fan, Induced DraftTypical Applications
Small to medium Industrial applications.
-
-
VXC Series (Counterflow)
-
VXC Series 'Counterflow' Evaporative Condenser
Capacity Range
Single Cell Capacity from 60kW to 6930kWFan System
Centrifugal Fan, Forced DraftTypical Applications
Sound sensitive industrial refrigeration projects. Installations with limited plan area. Indoor Installations.
-
-
VC1 Series (Containerised)
-
VC1 Series 'Containerised' Evaporative Condenser
Capacity Range
Single Cell Capacity from 950kW to 2000kWFan System
Centrifugal Fan, Forced DraftTypical Applications
Sound sensitive industrial refrigeration projects Installations with limited plan area; Indoor Installations.
-
-
CXV Series (Combinedflow)
-
CXV Series 'Combinedflow' Evaporative Condenser
Capacity Range
Single Cell Capacity from 300kW to 2100kWFan System
Axial Fan, Induced DraftTypical Applications
Industrial refrigeration applications.
-
-
VCL Series (Counterflow)
-
VCL Series 'Low Profile Counterflow' Evaporative Condenser
Capacity Range
Single Cell Capacity from 180kW to 1380kWFan System
Centrifugal Fan, Forced DraftTypical Applications
Sound sensitive industrial refrigeration and HVAC projects. Installations with extremely low height requirements. Indoor Installations. Skid packages.
-
-
RCC Series (Counterflow)
-
Water Saving Devices
-
HXI Series (Combinedflow)
-
HXI Hybrid Series 'Combinedflow' Closed Circuit Cooling Towers
Capacity Range
Single Cell Capacity from 45 to 150 l/sFan System
Axial Fan, Induced DraftMaximum Entering Fluid Temperature
82°CTypical Applications
Medium to large HVAC & industrial applications. Installations requiring plume abatement. Installation requiring water conservation. Low energy consumption. Easy maintenance.
-
-
HXC Series (Combinedflow)
-
HXC Hybrid Series 'Combinedflow' Evaporative Condenser
Capacity Range
Single Cell Capacity from 550kW - 2060kWFan System
Axial Fan, Induced DraftTypical Applications
Industrial refrigeration applications in geographical regions where water cost is high.
-
-
HXI Series (Combinedflow)
Submenu
If you have a question or would like to request more information regarding a product or service we offer at Pritchard, please complete the form below or contact us on the details provided.
In Person
6 Curban Street
Underwood
QLD 4119
Via Post
PO Box 597
Sanctuary Cove
QLD 4212
Via Phone / Fax
Phone: (07) 3219 0133
Fax: (07) 3341 9666
Via eMail
mail@pritchard.com.au
Please fill in the details below with as much detail as possible and we will have one of our dedicated staff members get back to you regarding your enquiry. Please note all the fields are mandatory.